GME30.07
First edition
Published on: 01/03/2005

30 extra deep BVP finish for non-refillable insert

Scope of application

Specifications and dimensions of the 30 extra deep finish concerning bore diameter and profile.
The finish is designed to take a non-refillable insert for ≤ or 150 cl bottles.

Table of contents

1. Scope
2. Definition
3. Comment
4. Normative references
5. Data sheet history
History
First edition: 04/2004
Revision I: 03/2005
Replaced on 01/2024 by data sheet GME30.10 - BORE SPECIFICATIONS FOR INSERTS FOR 30, 31,5 AND 35 SIZE BVP FINISHES

Contributors

ARDAGH GLASS GERMANY, ARDAGH GLASS PACKAGING SOUTH AFRICA, BA GLASS PORTUGAL, BRITISH GLASS, BUNDESVERBAND GLASINDUSTRIE, CSVMF, ENCIRC GLASS,FEVE, GERRESHEIMER BELGIUM, GERRESHEIMER GERMANY, HEINZ GLAS, O-I MANUFACTURING FRANCE, O-I MANUFACTURING ITALY, O-I MANUFACTURING UK, POCHET DU COURVAL, SAVERGLASS, STOELZLE-OBERGLAS, VERALLIA FRANCE, VERALLIA GERMANY, VETROPACK, VIDRALA, WIEGAND-GLASHUTTENWERKE

Document under responsibility of working group:

Glass wg3
WG chair: Niall MC GRATH - ENCIRC GLASS
This permanent group is dedicated to the creation and revision of Cetie's "GME*" neck finishes data sheets, and also to the revision of equivalent neck finishes data sheets previously submitted to official standardisation (ISO and/or CEN), dedicated to the production of glass bottles and jars for the food and beverage sectors. These neck finishes data sheets concern the following applications: ROPP, aluminum screw caps, crown caps, twist-off caps, cork or synthetic stoppers, bar-top, or swing stoppers.

*Initiated by the glass industry in the 1960s, the acronym 'GME' stands for 'Glass Manufacturing Experimental'. The idea was that Cetie, as an unofficial standards body, would only publish 'experimental' data sheets, before submitting these to the official standards bodies. At the same time, in the USA, the acronym 'GME' was also used. As the original meaning was lost over time, this nomenclature for Cetie's glass finishes documents has been, later on, applied to the PET finish data sheets.
Document suppressed from library
Cover - GME30.07 - 30 extra deep BVP finish for non-refillable insert